Key Features of Single Phase Transformer Less UPS 1:1
High reliability configuration
Double conversion online design, clean sine wave sources, frequency tracking, phase-locked, voltage regulation, low distortion, no power fluctuation interference, bypass mode available, built-in manual maintenance bypass switch, auto mode-switching by interlocks, unattended operation, cold start function.
Office environment design
Compact body design for office use, no noise operation, easy to lift.
N+X parallel redundancy
Unbalanced-rating paralleling technology, up to 8 paralleled units, auto load-sharing, flexible configuration & updating.
Wide input range
Input voltage range up to 20%, low battery mode switching frequency, long battery life, 45Hz ~ 65Hz auto sensing , high compatibility with local generators.
Digital Control
High speed DSP control units, intelligent battery management technology, auto battery floating charge switching, I/O voltage settings available through control panel.
Stable Operation
Stable & continuous power supply available under extreme grid conditions, SPWM technology, 6th generation IGBT module, optional Isolation Transformer, phase-loss resistance.
Comprehensive Protection
Output overload & short-circuit protection, battery fault & under-voltage protection, battery over-charging protection, inverter over-temperature protection, auto bypass mode switching, self-diagnosis function, remote EPO function.
User-friendly Communication
Optional LED / LCD display, status & statistics of operation display, optional RS232 / RS485 interface, external SNMP adapter, remote monitoring & management available.
Technical Specifications(single phase transformer less UPS 1:1):
Model
|
NP1100 Series
|
NP3100 Series
|
Capacity
|
1KVA ~ 10KVA
|
10KVA ~ 20KVA
|
Input Voltage
|
120VAC
~ 275VAC (1 phase)
|
210VAC
~ 475VAC (3 phase)
|
I/O Frequency
|
40Hz ~ 70Hz (auto sensing)
|
THD
|
<3% (linear load), <6% (non-linear load)
|
Crest Factor
|
3 : 1
|
Output Voltage
|
208VAC
/ 220VAC / 230VAC / 240VAC
|
Power Factor
|
0.8 (optional 0.9)
|
Overload
Ability
|
60”
/ 25” (110% / 150%)
|
Battery
Voltage
|
36VDC / 72VDC / 96VDC / 192VDC
|
192VDC
|
Transfer Time
|
0ms
|
Display
|
LED (optional LCD )
|
Interface
|
RS232
(optional intelligent slot / RS485 / DB9 dry contact)
|
Standards
|
EMI: IEC62040-2; EMC: IEC61000-4
|
Note: IP22 enclosure (optional IP55
enclosure for outdoor use); optional voltage 110VAC -/+15%; optional
isolation transformer, surge protector.
|