General(1500VA Offline NEO UPS): The 500VA Offline NEO UPS offers only the most basic features, providing surge protection and battery backup. With this type of UPS, a user's equipment is normally connected directly to incoming utility power with the same voltage transient clamping devices used in a common surge protected plug strip connected across the power line.
Features(1500VA Offline NEO UPS): (1) High reliability is guaranteed because the battery back-up adopted microprocessor control system; (2) The UPS is equipped with Boost and Buck AVR to stabilize input voltage; (3) Built-in DC start function enables UPS to be started up without AC power supplied; (4) Smart RS232 communication port with Free Download Software from the Internet; (5) Auto restart while AC recovery; (6) Compact size, light weight; (7) it can provide modem and phone line surge protection; (8) The electric power supply device can provide overload protection; (9) USB is optional.
Technical Specification(1500VA Offline NEO UPS):
MODEL |
KS500 |
KS600 |
KS800 |
KS1000 |
KS1500 |
KS2000 |
Capacity |
VA/W |
500VA/300W |
600VA/360W |
800VA/480W |
1000VA/600W |
1500VA/900W |
2000VA/1200W |
Input |
Phase |
Single |
Voltage |
110/120VAC or 220/230/240VAC |
115VAC or 220/230/240VAC |
Voltage Range |
81~145VAC/140~290VAC±5% |
85~140VAC/162~290VAC±5% |
Frequency |
50Hz/60Hz(Auto Sensing) |
Frequency Range |
45~55Hz/55~65Hz |
Output |
Phase |
Single |
Waveform |
Modified Sinewave |
Voltage (Btt. Mode) |
110/120VAC or 220/230/240VAC |
115VAC/230VAC |
Voltage Regulation |
±10% |
Frequency |
50Hz/60Hz |
Frequency Regulation (Battery Mode) |
±1Hz |
Power Factor |
P.F. |
0.6 |
0.6 |
0.6 |
0.6 |
0.6 |
0.6 |
Battery |
Battery Type |
12V/7AH |
12V/7AH |
12V/9AH |
12V/7AH |
12V/9AH |
12V/9AH |
Number |
1PCS |
1PCS |
1PCS |
2PCS |
2PCS |
2PCS |
Back up Time (at a PC loadwith15", monitor) |
20 minutes |
20 minutes |
29 minutes |
35-40 minutes |
45-50 minutes |
45-50 minutes |
Recharge Time |
8 hours to 90% after complete discharge |
Transfer Time |
Typical |
4-6ms |
Indictor |
AC mode |
Green LED lighting |
The 1st green LED lighting; The 2nd to 5th green LEDs gradually lighting indicating load capacity |
Battery Mode |
Yellow LED flashing every 10 seconds |
The 1st green LED flashing every 10 seconds |
Fault |
Red LED lighting |
Audible Alarm |
Battery Mode |
Sounding every 10 seconds |
Low Battery |
Sounding every second |
Overload |
Sounding every 0.5 second |
Battery Replacement |
Sounding every 2 seconds |
Fault |
Continuously sounding |
Protection |
Full Protection |
Discharge, Overcharge, and Overload Protection |
Physical |
Dimension (mm) |
330*100*140 |
349*146*160 |
368*140*180 |
Net Weight (kg) |
5 |
6 |
6.5 |
13.8 |
14.2 |
16 |
Environment |
Operating Environment |
0~40 Degrees Centigrade, 0~90% relative humidity (non-condensing) |
Interface |
Smart RS232 |
Support Windows family, Linux, IBM Aix, Sun Solaris, Compaq True 64, UnixWare, FreeBSD, HP-UX, and MAC |
USB |
Option | |